ProLine G2 Simplification Plan

ProLine G2 to be phased out

To make it easier and more convenient for customers to identify and select the protection solutions they need, we are streamlining our portfolio to modular floor-standing enclosures, wall-mounted enclosures, and terminal boxes. We will be phasing out the ProLine G2 enclosure range as of:

 

ProLine G2 Timeline

 

The highly recommended substitutes for each of these ranges in our global product portfolio are as follows:

  • The MCS-MCD modular floor standing enclosures to substitute the ProLine G2 range.
  • Please Note that this does not include DATACOM solutions.

During the interim transition period, we will work closely with customers to provide support. Below you will find more details.

PRODUCT

RANGES TO BE PHASED OUT

SUBSTITUTED BY

Modular Enclosures

ProLine G2 Modular Enclosure

ProLine G2 Modular

Modular MCS-MCD

Modular MCS

Modular MCD

WHEN AND HOW WILL PROLINE G2 BE PHASED OUT?

The ProLine G2 range will be phased out for all markets as follows:

ActionDeadline
No more quotes or SPAsSeptember 1, 2023
Stop taking ordersMarch 1, 2024
ObsoleteSeptember 1, 2024

 

Please note:

  • Products will be delivered after phasing out deadline only if stock remains available.
  • Ongoing projects for customized ProLine G2 products will be reviewed with customers to assess and define the transition timeline and conditions.
  • nVent Hoffman will support projects with high complexity by assigning dedicated engineering resources. For further details, please contact your Sales Representative.

WHICH SPECIFIC ENCLOSURES WILL BE PHASED OUT? AND WHAT ARE THE RECOMMENDED SUBSTITUTES?

 

ProLine G2 Modular Enclosures ProLine Product Substituted by Mild steel modular enclosure, single door P2KMCS Mild steel modular enclosure, double door P2KODMCD Mild steel modular enclosure, single door P2K-3RMCS-3R Mild steel modular enclosure, double door, 3RP2KOD-3RMCD-3R On Request

Information_Icon_black_2.png

Please note:

As of September 1st, 2023, nVent HOFFMAN will no longer maintain stock of accessories and replacement parts for the ALED ranges or feature them as available products online or in other media. However, nVent HOFFMAN will manufacture these accessories and replacement parts upon request.

ARE THERE DIMENSION, DESIGN OR OTHER DIFFERENCES BETWEEN THE PRODUCTS BEING PHASED OUT AND THEIR SUBSTITUTES?

Yes, there are slight differences between some of the models and their substitutes. The main differences are listed below.

Modular Floor-Standing Enclosures

ProLine G2 versus MCS (single door) and MCD (double door)

 

Enclosure Fixation

ProLine G2MCS-MCD
Corner piece fixation:
37.5 mm from the front/rear
34.5 mm from the side
Corner piece fixation:
34.5 mm from the front/rear
34.5 mm from the side
Floor fixation:
37.5 mm from the front/rear
57 mm from the side
Floor fixation:
62.5 mm from the front/rear
62.5 mm from the side

Mounting Plate Dimensions

ProLine G2MCS-MCD
Useful height: Nominal height – 94 mmUseful height: Nominal height – 115 mm
Useful width: Nominal width – 72 mmUseful width: Nominal width – 70 mm

Locking System

ProLine G2MCS-MCD
HandleLock cover in single and double door, handle available as an accessory
3 locking points4 locking points

Lifting Eyebolts

ProLine G2MCS-MCD
IncludedAvailable as an accessory

Load Rating

ProLine G2 (lb/kg)MCS-MCD (lb/kg)
Frame: 3000/1587
Safety Factor: 1.5
Frame: 3057/1386
Safety Factor: 1.25
Mounting Plate: 2000/907
Safety Factor: 2.5
Mounting Plate: 1349/612
Safety Factor: 1.25
Door: 250/113
Safety Factor: 1.5
Door: 202/92
Safety Factor: 1.25
Rear Panel: 300/136
Safety Factor: 1.5
Rear panel: 202/92
Safety factor: 1.25
Side Panel: 300/136
Safety Factor: 1.5
Side panel: 220/100
Safety factor: 1.25
Bottom Plates: 200/90
Safety Factor: 1.5
Bottom Plates: 200/90
Safety factor: 1.25

Note: MCS-MCD loading capacity has been tested in order to fulfill with European market specifications, however, it does not mean that the values from above table are the highest.

FAQs

Accessories and Replacements 

Question

How do I order an accessory or replacement part for the current ProLine G2 ranges?

 

Will this transition include DATACOM solutions?

Answer

If you know the item number, you can proceed to order as usual. If you do not know the item number, please contact your nearest nVent HOFFMAN sales representative.

No, this transition does not include DATACOM solutions.

Standard and Customized enclosures

Question

Does nVent HOFFMAN guarantee that I will be able to order standard ProLine G2 enclosures?

 

Can I order customized solutions for the ranges that are substituting ProLine G2?

Answer

Although ProLine stock will be reduced gradually before discontinuing ProLine G2, nVent HOFFMAN will continue to manufacture ProLine G2 enclosures until the last manufacturing date.

Yes, nVent HOFFMAN will continue offering customized enclosures to meet the unique requirements of each individual customer, including special dimensions, custom colors, transparent windows, ventilation louvers, welded studs, increased corrosion resistance, holes, threading, and more.

Others 

Question

Do the substitute ranges of enclosures give the same protection ratings as ProLine G2 enclosures?

Who can I contact for more information? 

Answer

Yes, the substitute enclosures achieve the same IP rating according to IEC 60529, and the same NEMA TYPE rating.